Advanced Handheld Fiber Test Kits

$2,713.24 – $4,214.67
Title Description Price Resellers
TK076 Advanced Test Kit for Singlemode and Multimode $4214.67
TK077 Advanced Test Kit for Singlemode $3376.17
TK081 Pocket Light Source and Handheld Power Meter for Singlemode $2713.24

Tempo Handheld Fiber Test Kits pair optical power meters with stabilized light sources to give technicians a reliable, field-ready solution for measuring optical power, insertion loss, and fiber continuity. Available in singlemode, multimode, standard, and high-power configurations, these kits support everyday fiber testing as well as more application-specific needs like out-of-band testing and tone identification. Choose the kit that matches your network, wavelength requirements, and testing workflow.

Typical testing applications

  • Optical power at 25 calibrated wavelengths, -60 to +15 dBm range.
  • Optical loss on SM fiber 1310 / 1550 nm, 60 dB range.
  • Optical loss on MM fiber 850 / 1300 nm, 40 dB (@ 62.5um) range, EF compliant.
  • Loss testing automation & reporting with AutoTest and KITS™ software.
  • Optical continuity / tone checking, 12 fiber Multi-Fiber ID, 50 dB range.
  • Generally meets safety regulations & standards based test procedures.

Connector & battery summary

SC interchangeable connector adapters.
Meter accepts PC & APC polish. Source accepts PC polish.
Meter 2 x AA alkaline. Run time >1000 hours. Micro USB pwr /charging.
Source 2 x AA alkaline. Run time >80 hours. Micro USB pwr /charging.

Includes:

  • LED & LASER QUAD OPTICAL TEST SOURCE T2824
  • HANDHELD OPTICAL POWER METER T2600
  • PADDED CANVAS CARRY POUCH OPT149
Attribute name Attribute Value
ModelTK076TK077TK081
Detector typeInGaAs

Calibration accuracy1% (0.06 dB)

Response wavelength600 ~ 1700 nm

Calibration wavelengths780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm

Power range+10 ~ -60 dBm (for 780 ~ 980 nm) / +10 ~ -70 dBm (for 1270 ~ 1650 nm)

Mid-range linearity0.04 dB (typical)

Total uncertainty0.3 dB (max)

Wavelength sensitivity (± 30 nm)0.03 dB (typical)

ID tone detection & Autotest sensitivityUp to -50 dBm

Available Accesories

OPT076 TEST SET ADAPTOR SC/LC METAL BODY CERAMIC SLEEVE
OPT076 TEST SET ADAPTOR SC/LC METAL BODY...
TEST SET ADAPTOR SC/LC METAL BODY CERAMIC SLEEVE