Two-Way Optical Loss, Length & ORL Test Sets – T23400 Series

$4,942.45 – $8,338.89
Title Description Price Resellers
T23403OLV-APC-50U 850-1300nm LED, APC, ORL @50U, INGAAS $4942.45
T23422OLV 1310-1500nm Laser, INGAAS $6176.52
T23424OL-APC 850-1300nm LED, 1310-1550nm U/S Laser, APC, INGAAS $8338.89

A Quad Two-Way Optical Loss Test set / OLTS fiber tester that’s perfect for medium to ultra high fiber count loss, length & optical return loss testing applications on both multimode and single mode fiber with APC connectors on both ports at 850 / 1330nm 1310/1550 nm. A pair of these compact SM & MM instruments set new standards of productivity, ultra-stable source accuracy and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.

Each fiber needs just one test hook-up and one key press for a complete bidirectional loss, length & ORL test, and the same test method is used for both multimode and single mode fiber, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.

The optical fiber length measurement feature is accurate, integrated with the other measurements, and requires only one fiber to be hooked up.

A pair of instruments both display length, bi-directional loss & ORL each end in real time, with no need to specify master/slave instruments. A single OLTS instrument can also be used as a stand-alone ultra-stable light source, power meter, ORL meter or tone generator / detector.

  • 25% of the size / weight, 7x the battery life of competitors
  • Bidirectional Autotest loss, length & ORL testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass / Fail display
  • 8,000 fiber memory and USB Flash Drive file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1 % accuracy
  • Traceable calibration reports: power meter & linearity, source λ & stability, ORL
  • 80 hr alkaline battery life
  • 3 Year warranty and calibration cycle
  • EF compliant multimode sources
  • Made in Australia
Attribute name Attribute Value
Output wavelength (source)Port 1: 1310, 1550 nm Laser APC / Port 3: 850, 1300 nm LED APC1310-1550 nm Laser, VisiTester
850-1300 nm LED APC, VisiTester
Output power (source)-3 dBm ±1 dB (@ 9/125 µm for 1310, 1550 m) / -23 dBm ±1 dB (@ 62.5/125 µm for 850, 1300 nm)-7 dBm ±1 dB @ SMF
-27 dBm ±1 dB @ 62.5 µm
Adjust output power (source)Adjustable over 7 dB in 0.01 dB steps (for 1310, 1550 nm) / Fixed (for 850, 1300 nm)Adjustable over 7 dB in 0.01 dB steps
Fixed
Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source)0.03 dB (for 1310, 1550 nm) / 0.01 dB (for 850, 1300 nm)0.03 dB
0.01 dB
Stability over temperature (source)0.2 dB (max for 1310, 1550 nm) / 0.35 dB (max for 850, 1300 nm)0.2 dB (max)
0.35 dB
Wavelength initial tolerance @ 25 °C (source)20 nm (for 1310, 1550 nm)20 nm

Wavelength drift (source)0.4 nm per °C (typical for 1310, 1550 nm) / 0.4 nm per °C (typical for 850, 1300 nm)0.4 nm per °C (typical)
0.4 nm per °C (typical)
Mode controlled (source)850, 1300 nm (50/125µm compliant: IEC 61280-4-1 {Ed.1.0}, TIA 526-14A & TIA TSB-178)
50/125µm compliant: IEC 61280-4-1 {Ed.1.0}, TIA 526-14A & TIA TSB-178
Spectrum width @ FWHM (source)3 nm (typical for 1310, 1550 nm)3 nm (typical)

Reconnection repeatability @ 95% confidence (source)0.1 dB (for 1310, 1550 nm Laser) / 0.05 dB (for 850, 1300 nm LED)0.1 dB

Length range (2-way Autotest only)6 dB @ 62.5 µm (for 850, 1300 nm) / 30 dB (for 1310, 1550 nm)27 dB
4.5 dB @ 50 µm
Length accuracy (2-way Autotest only)0.01% ± 4 meters0.01% ± 4 meters
0.01% ± 4 meters
Length resolutions1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km)1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km)
1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km)
Loss range (2-way Autotest)27 dB @ 62.5 µm (for 850, 1300 nm) / 47 dB (for 1310, 1550 nm)44 dB
21.5 dB @ 50 µm
Loss repeatability & loss linearity (2-way Autotest)0.06 dB (for 850, 1300 nm) / 0.04 dB (for 1310, 1550 nm)0.04 dB
0.06 dB21.5 @ 50 µm21.5 @ 50 µm
Loss range (1-way Autotest)27 dB @ 62.5 µm (for 850, 1300 nm) / 47 dB (for 1310, 1550 nm)44 dB
21.5 @ 50 µm
Loss repeatability & loss linearity (1-way Autotest)0.06 dB (for 850, 1300 nm) / 0.04 dB (for 1310, 1550 nm)0.04 dB
0.06 dB
ORL range0 ~ >60 dB (1310, 1550 nm) / 0 ~ 30 dB @ 62.5 µm0 ~ >60 dB
0 ~ 27.5 dB @ 50 µm
ORL port isolation> 60 dB (1310, 1550 nm) / > 25 dB (850, 1300 nm)> 60 dB
> 25 dB
ORL resolutionFor 1310, 1550 nm: 0.01 dB (@ 0 ~ 50 dB), 0.1 dB (@ 50 ~ 65 dB) / For 850, 1300 nm: 0.01 dB (@ 0 ~ 30 dB), 0.1 dB (@ 30 ~ 45 dB)0.01 dB (@ 0 ~ 50 dB), 0.1 dB (@ 50 ~ 65 dB)
0.01 dB (@ 0 ~ 30 dB), 0.1 dB (@ 30 ~ 45 dB)
ORL accuracy0.2 dB0.2 dB
0.2 dB


Detector type (meter)InGaAsInGaAs
InGaAs
Response wavelength (meter)600 ~ 1700 nm600 ~ 1700 nm
600 ~ 1700 nm
Calibration wavelengths (meter)780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
Accuracy (meter)1 % (0.06 dB)1 % (0.06 dB)
1 % (0.06 dB)
Mid-range linearity (meter)0.04 dB (typical)0.04 dB (typical)
0.04 dB (typical)
Power range (meter)+10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm)+10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm)
+10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm)
Total uncertainty (meter)0.3 dB (max)0.3 dB (max)
0.3 dB (max)
Resolution (meter)0.01 dB0.01 dB
0.01 dB
Polarization sensitivity (meter)< 0.05 dB (typical)< 0.05 dB (typical)
< 0.05 dB (typical)
ID tone detection & Autotest sensitivity (meter)Up to -50 dBmUp to -50 dBm
Up to -50 dBm
Autotest:1-way: compatible with other T23400 & T27400 models / 2-way: compatible with identical model only1-way: compatible with other T23400 & T27400 models / 2-way: compatible with identical model only
1-way: compatible with other T23400 & T27400 models / 2-way: compatible with identical model only
Tone detection (meter)150 ~ 9999 Hz ± 1 %150 ~ 9999 Hz ± 1 %
150 ~ 9999 Hz ± 1 %
USB interfacesmicro-USB for power & software / USB-A Flash DriveUSB-micro for power & software / USB-A for memory key
micro-USB for power & software / USB-A Flash Drive
SoftwareKITS (free download)KITS (free download)
KITS (free download)
PowerBattery / External power via micro-USBBattery / External power via USB
Battery / External power via micro-USB
Battery lifeLaser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical)Laser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical)
Laser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical)
Battery type2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via micro-USB)2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via USB)
2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via micro-USB)
Auto offSelectableSelectable
Selectable
Display74 mm x 55 mm high contrast LCD74 mm x 55 mm high contrast LCD
74 mm x 55 mm high contrast LCD
CasePolycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop testedPolycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested
Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested
MemoryFor 8,000 fibers / Unlimited on USB Flash DriveFor 8,000 fibers / Unlimited on USB
For 8,000 fibers / Unlimited on USB Flash Drive
Size190 mm x 105 mm x 35 mm190 mm x 105 mm x 35 mm
190 mm x 105 mm x 35 mm
Unit weight0.42 kg0.42 kg
0.42 kg
Shipping weight1.5 Kg1.5 Kg
1.5 Kg
Operating / storage temperature-15 to 55 °C / -25 to 70 °C-15 to 55 °C / -25 to 70 °C
-15 to 55 °C / -25 to 70 °C
Relative humidity0 ~ 95 %0 ~ 95 %
0 ~ 95 %
Warranty3 years3 years
3 years
Calibration validity (ISO/IEC 17025)3 years3 years
3 years
Country of OriginAustraliaAustralia
3 years

Available Accesories

OPT076 TEST SET ADAPTOR SC/LC METAL BODY CERAMIC SLEEVE
OPT076 TEST SET ADAPTOR SC/LC METAL BODY...
TEST SET ADAPTOR SC/LC METAL BODY CERAMIC SLEEVE

Related Products